Product specification
Performance properties |
Strain range |
±5000μɛ
|
|
Accuracy (guaranteed)1) |
<0.35% FS3) | ||
Accuracy (typical)1) |
<0.18% FS3) | ||
Precision (guaranteed)2) |
<0.15% FS3) | ||
Precision (typical)2) |
<0.10% FS3)
|
||
Temperature compensation | Integrated | ||
Temperature accuracy1) |
<1°C
|
||
Temperature precision2) |
±0.3°C
|
||
Temperature resolution |
0.05°C
|
||
Temperature sensitivity |
28pm/°C
|
||
Strain sensitivity |
∽1.35pm/µɛ
|
||
Operating Temperature range | -20°C to +60°C | ||
Ingress Protection rating |
IP 67
|
||
Physical properties |
Housing material |
Stainless steel SS316L and polyamide
|
|
Anchoring distance |
Adjustable parameter | ||
Dimensions (without cable)4) |
Ø12 mm x L mm [Washer Ø24 mm] | ||
Weight (without cable) |
450g | ||
Cable type |
3mm Dyneema reinforced cable
|
||
Cable length5) | 1mtr | ||
Cable Bend Radius (dynamic) |
40mm
|
||
Cable Bend Radius (static) |
30mm
|
||
Connector type6) |
FC/APC | ||
Mounting method | Mounting brackets | ||
Packaging | Cardboard box – dimensions depending on the final configuration. | ||
Quality Statement | SC-01 sensor is compliant with IEC 61757-1-1:2020, IEC 61757-2-1:2021 and IEC 61757:2018 All sensors are 100% tested and calibrated at SYLEX. Sensor is manufactured according to ISO 9001:2015 and ISO 14001:2015 |
Notes:
- 1) Accuracy is established for each individual sensor under laboratory conditions and it includes hysteresis, non-linearity and repeatability of the sensor.
- 2) Precision is established on a batch basis and it includes hysteresis, non-linearity, repeatability and reproducibility of the sensor.
- 3) FS: full scale range
- 4) For further dimensions details see the product drawing
- 5) Cable length is extendable on request
- 6) Other connector types available on request